Metering time definitions and configuration ID
The market communication object that defines which quarter hour falls into which meter register – the basis for time-variable grid fees and time-variable tariffs on a smart metering system.
An HT/NT meter used to know by itself when night falls: a time switch or ripple control receiver flipped the register, and the grid operator had the times written down somewhere in a PDF. With time-variable grid fees and dynamic tariffs that is no longer enough. The time windows have to be exchanged between market partners as data – that is the Zählzeitdefinition (metering time definition).
What a metering time definition is#
A Zählzeitdefinition assigns exactly one Zählzeitregister (metering time register) to every point in a calendar. It consists of a unique identifier, a validity period and a set of time windows that together cover every quarter hour of the year – without gaps and without overlaps. From the register-reading series of an iMSys the consumption per register can then be formed: each quarter hour is assigned to a register by its timestamp and summed there.
- Zählzeitregister
- The target of the assignment – for example “peak”, “standard”, “off-peak”, or classically HT and NT. Functionally it corresponds to the register of a multi-rate meter but exists as a computed register, not necessarily as hardware.
- Time window
- A period within a day type – say weekdays 17:00 to 20:00 – assigned to a register. Day types distinguish weekday, Saturday, Sunday and public holiday.
- Konfigurations-ID (configuration ID)
- The identifier of the specific bundle of metering time definition, registers and assignments that applies at a market location. If the bundle changes a new ID is created – so it stays unambiguous under which configuration a value was formed.
Who defines – and for what#
| Defined by | Purpose | Example |
|---|---|---|
| Grid operator | Time-variable grid fees, in particular Module 3 under § 14a EnWG | Three time windows per grid area with peak, standard and off-peak prices |
| Supplier | Time-variable tariff towards the customer | Two registers for an HT/NT tariff or several stages for a time-of-use tariff |
From quarter hour to register#
- 1
Obtain the time series
The register-reading series (TAF 7) delivers a meter reading every 15 minutes; the differences are the quarter-hour consumptions. Alternatively the gateway forms the register values itself (TAF 2) once the metering time definition has been loaded via the gateway administrator.
- 2
Determine the day type
For every calendar day: weekday, Saturday, Sunday or public holiday – according to the holiday calendar the definition prescribes.
- 3
Assign the time window
Each quarter hour is assigned to the matching time window, and thus a register, by day type and time of day.
- 4
Aggregate
Consumption per register is summed over the billing period and billed like register consumption – at the price of the respective register.
Three registers on one weekday (simplified)
- Peak 17:00–20:00, 12 quarter hours at 0.75 kWh
- 9 kWh
- Off-peak 00:00–06:00, 24 quarter hours at 0.25 kWh
- 6 kWh
- Standard, remaining 60 quarter hours at 0.30 kWh
- 18 kWh
Calendar, public holidays, clock changes#
The assignment hangs on three things that each look harmless and together produce most of the errors.
- Public holidays
- Are a matter for the federal states in Germany. Corpus Christi is a holiday in Bavaria but not in Hamburg. The grid operator determines which holiday calendar applies in its grid area – and whether a holiday is treated like a Sunday.
- Summer and winter time
- The day of the switch to summer time has 23 hours (92 quarter hours), the day of the switch back 25 hours (100 quarter hours). In October the quarter hours between 02:00 and 03:00 local time occur twice.
- Time zone of the metered values
- Gateways and market communication work in UTC. A time window “17:00 to 20:00”, however, is local time. The conversion has to be done per calendar day, not with a fixed offset.
Relation to HT/NT and § 14a Module 3#
A classic two-rate meter is the special case of a metering time definition with two registers, fixed switching times and an implementation in hardware. The Zählzeitdefinition generalises that: any number of registers, day-type-dependent windows, changeable each year, implemented as a calculation rule on quarter-hour values. For § 14a Module 3 that is exactly the technical precondition – the grid operator defines at least three time windows with different unit rates in the grid fee, and without an iMSys and a metering time definition that cannot be billed.
What a billing engine needs#
- A time zone calendar with public holidays per federal state or per grid area, including the rules for clock-change days
- Metering time definitions as versioned master data with a validity period – the definition for 2026 must not overwrite the one for 2025, because corrective invoices still need the old one
- The configuration ID on every register value formed from it, so it remains traceable under which rule it came about
- Two parallel assignments per market location: one for the grid fee (the grid operator's definition), one for the tariff (the supplier's definition)
- A checksum test against total consumption and error handling for quarter hours without an assignment
- The fallback to the registers of a multi-rate meter where no iMSys is installed – there the meter delivers the register readings, and the metering time definition only documents the switching times