Standard load profiles and metered load

Up to 100,000 kWh a year a statistical curve spreads annual consumption across the hours; above that, actual load is metered every quarter hour.

Updated: August 2026

The market balances per quarter hour – but a household meter is read once a year. The standard load profile closes that gap: a normalised curve stating how a typical customer spreads their annual consumption across the year.

Standard load profile or metered load curve?

How consumption is spread across the day

interactive
00:0006:0012:0018:0024:00

Daily consumption

10.1 kWh

Peak load

0.8 kW

Measurement

1× im Jahr

Up to 100,000 kWh a year the market works with a standard load profile (SLP): annual consumption is spread across the hours along a statistical curve. Above that – and for every customer with load metering – the actually metered load curve (RLM) counts, in quarter-hour intervals.

The common profiles#

ProfileCustomer group
H0household
G0 – G6commercial, split by daily pattern – G4 retail, G5 bakery, G6 weekend operation
L0 – L2agriculture
SLP gasadditionally temperature-dependent, via degree days

When RLM applies#

  • Electricity: from 100,000 kWh of annual consumption (§ 12 StromNZV)
  • Gas: from 1.5 million kWh a year or from 500 kWh/h of hourly offtake (§ 24 GasNZV) – gas works in hourly values rather than quarter hours
  • Measurement in quarter-hour intervals, transmitted daily to the grid operator
  • The basis for the capacity charge and for reactive energy
  • Also possible for smaller customers where an iMSys is installed