Balancing groups
A virtual account where a supplier's injections and withdrawals must balance every quarter hour – the commercial basis that makes energy tradable at all.
Because individual kilowatt-hours cannot be traced through the grid, the market works with accounts instead. Every supplier runs at least one balancing group – itself or through a service provider. Everything its customers withdraw is booked there as a debit, everything it procures as a credit.
The quarter hour sets the beat#
Balancing happens per quarter hour. For each of those 96 periods a day the balancing group must add up. If it does not, the transmission grid operator supplies balancing energy – at a price deliberately made unattractive, so that forecasting well pays off. It is settled by the ÜNB in its role as Bilanzkoordinator (BIKO), the balancing coordinator with whom every balancing group manager holds a balancing group contract.
Where the volumes come from#
For customers with registering load metering, the metered load curve supplies the real values. For everyone else – which is practically every household – the market works with a standard load profile. The difference between profile and reality is settled by the grid operator through Differenzbilanzierung, residual balancing.
Standard load profile or metered load curve?
How consumption is spread across the day
interactiveDaily consumption
10.1 kWh
Peak load
0.8 kW
Measurement
1× im Jahr
Up to 100,000 kWh a year the market works with a standard load profile (SLP): annual consumption is spread across the hours along a statistical curve. Above that – and for every customer with load metering – the actually metered load curve (RLM) counts, in quarter-hour intervals.
The MaBiS timeline#
Balancing group settlement is not a real-time process. The Marktregeln für die Bilanzkreisabrechnung Strom (MaBiS), the market rules for electricity balancing group settlement, define when which data flows:
- 1
Delivery month
The grid operators aggregate the volumes per balancing group – load curves from metering, standard load profiles from the forecast – and report them to the BIKO.
- 2
Bilanzkreisabrechnung
Around two months after the delivery month the BIKO settles the balancing energy per balancing group. The basis is the time series reported and reconciled between the parties by then.
- 3
Korrekturbilanzkreisabrechnung
Around eight months after the delivery month a correction settlement follows, using the metered values delivered late or corrected in the meantime. Only then is the month finally closed for the balancing group.
In parallel, the grid operator settles the Mehr-/Mindermengen (surplus and shortfall quantities) with the supplier: the difference between the profile volumes that were balanced and the consumption actually metered for its customers.
Gas balances differently#
In the gas market the balancing period is not the quarter hour but the Gastag, the gas day from 06:00 to 06:00 the next morning (daily balancing). The network itself buffers within the day. The responsible party is not a transmission operator but the Marktgebietsverantwortlicher (MGV), the market area manager – since 2021 Trading Hub Europe (THE) for all of Germany. The rules are called GaBi Gas rather than MaBiS, the balancing group manager acts towards the grid operators as a Transportkunde (transport customer), and households are balanced via standard load profiles that depend mainly on the daily temperature.