Jump to Content

The gas market: market area, balancing, levies

One market area, one gas day, one balancing authority: the gas market follows its own rules – from the entry-exit logic to the levies that appear only on a gas bill.

Updated: August 2026

Anyone coming from electricity recognises much of the gas market – suppliers, grid operators, balancing groups, market communication – and then stumbles over the differences: there are no control areas but one market area. Balancing is not per quarter hour but per day. And the gas itself is not measured in kWh but in cubic metres, which only billing translates into energy.

One market area: Trading Hub Europe#

Since 1 October 2021 Germany has had a single gas market area, run by Trading Hub Europe GmbH (THE) as Marktgebietsverantwortlicher (MGV, market area manager). Before that there were two (NetConnect Germany and Gaspool), and earlier up to 19. The MGV is a joint venture of the transmission system operators and does what the four TSOs do as balancing coordinators in electricity – for all of Germany in one place.

Entry-exit system
Shippers book capacity separately for entry into the market area (entry: border points, storage, biogas plants, LNG terminals) and exit (exit: offtake to distribution grids and end customers). Between entry and exit sits the Virtueller Handelspunkt (VTP, virtual trading point), where gas is traded and transferred between balancing groups without reference to a physical location.
Gas day
The balancing day runs from 06:00 to 06:00 the following day. All quantities, nominations and allocations refer to the gas day, not the calendar day – meter readings at the turn of the month are also calculated for 06:00.
Daily balancing
The balancing group must be balanced over the gas day. Within the day the grid buffers (line pack). The MGV settles deviations as imbalance energy; in addition there are hourly tolerances and an intraday flexibility charge for RLM customers.

SLP and RLM in gas#

The threshold for interval metering is much higher in gas than in electricity: 1.5 million kWh annual consumption or 500 kWh/h offtake capacity (§ 24 GasNZV) – practically all households and most commercial customers are SLP customers, see load profile. RLM customers are metered hourly and balanced daily via MSCONS.

Gas standard load profiles are above all temperature-dependent: they describe daily consumption as a sigmoid function of the daily mean temperature – near zero at 20 °C (only hot water and cooking), near the maximum at −10 °C. Balancing uses the previous day's forecast temperature; the difference between forecast and actual consumption is not borne by the supplier but spread over all SLP exit points via the balancing levy. A warm winter is therefore no balancing group risk for a gas supplier – but a sales volume risk.

The rulebooks: GaBi Gas and GeLi Gas#

The Bundesnetzagentur has issued sister decisions to the electricity rules for gas: GeLi Gas (business processes for supplier switching in gas) corresponds to the GPKE and governs registration, deregistration and re-registration; GaBi Gas (basic model of balancing service and balancing rules) corresponds to MaBiS. Ruling chamber 7 is responsible. The formats are the same EDIFACT messages as in electricity – UTILMD, MSCONS, INVOIC – with gas-specific codes; since 1 October 2025 transported via AS4 in gas as well.

Levies that appear only on the gas bill#

ItemWhat forWho sets it
Bilanzierungsumlage (balancing levy, SLP and RLM separately)Covers the cost of balancing energy and the difference between balanced SLP quantities and actual consumption; formerly called RegelenergieumlageMGV, annually on 1 October
Konvertierungsumlage (conversion levy)Cost of balancing H-gas and L-gas as one commodity in the same market area although they flow physically separatedMGV, annually
Gasspeicherumlage (gas storage levy, § 35e EnWG)Since October 2022 to finance the state-mandated filling of storage; its abolition from 1 January 2026 has been decided – the federal government takes over the costby statute; amount most recently set by the MGV
Energy tax0.55 ct/kWh for natural gas used for heating (§ 2 Abs. 3 EnergieStG), see energy taxfederal government
CO₂ priceNational emissions trading under the BEHG, in 2026 within a price corridor of 55 to 65 €/t – see CO₂ pricefederal government
Add [[netzentgelte|grid fees]], [[konzessionsabgabe|Konzessionsabgabe]] and VAT as in electricity. The composition in detail: [[gaspreis-zusammensetzung|gas price composition]].

H-gas, L-gas and the market area conversion#

Germany historically has two gas qualities: high-calorific H-gas and low-calorific L-gas from Dutch and northern German fields. Because L-gas production is running out, entire grid areas in north-western Germany are being converted to H-gas – the Marktraumumstellung (market area conversion), in which every gas appliance has to be adjusted or replaced. For billing that means a jump in the calorific value on the conversion date; the details are under natural gas.

Biomethane#

Upgraded biogas is injected into the natural gas grid as biomethane and is physically indistinguishable there. It is therefore traded via dedicated biogas balancing groups with a balancing period of twelve months and via certificates in the dena biogas register. For the supplier, biomethane is a procurement and certification topic – on the customer's bill it appears as a product attribute, not as a separate line.

Related topics

Sources & further reading