Thermal gas billing
Gas volume is measured in m³ and converted into kWh using the state number and the calorific value, so the energy is billed independently of pressure and temperature.
A cubic metre of gas is not a fixed amount of energy. More gas fits into the same cubic metre in a cold cellar than in a warm one, and gas from Norway carries more energy than gas from another source. So that everyone still pays for the same product, the market converts to energy.
Consumption [kWh] = Volume [m³] × Zustandszahl z × Calorific value [kWh/m³]
- Volume
- the difference between the meter readings, in operating cubic metres
- z
- the Zustandszahl, correcting for pressure and temperature – typically 0.90–0.98 for low-pressure household connections, above 1 at higher billing pressures
- Calorific value
- the calorific value of the gas delivered; typically 8.4–13.1 kWh/m³
The grid operator supplies both factors, and both must be shown on the invoice.
Converting a gas meter into kilowatt-hours
The meter measures volume, the invoice counts energy
interactiveThe calorific value and the Zustandszahl appear on every gas invoice and come from the grid operator. The calorific value varies with gas quality (L-gas around 8.4–11.2 kWh/m³, H-gas around 10–13.1 kWh/m³), the Zustandszahl with altitude and supply pressure – typically 0.90 to 0.98.
Worked example#
Annual statement for a detached house
- Meter reading, new
- 08,412 m³
- Meter reading, old
- 06,902 m³
- Volume
- 1,510 m³
- Zustandszahl
- 0.9540
- Calorific value
- 11.208 kWh/m³
Why customers baulk here#
The meter shows 1,510 – the invoice says 16,146. This is the single most common source of enquiries in the gas business. A portal that puts both figures side by side and shows the chain of arithmetic measurably reduces contacts to customer service.