The location model of market communication
Market location, metering location, grid location, technical and controllable resource: five objects that together describe where energy is traded, metered, handed over to the grid, generated and controlled.
To the customer, a house with photovoltaics, a battery and a heat pump is one connection with one bill. To market communication it is half a dozen objects with their own IDs, their own responsible parties and their own life cycles. The location model defines which objects those are – and who is allowed to manage which of them.
The reason for the decomposition is always the same: each question should be answered by exactly one object. “Who supplies here?” is a different question from “Which device measures?”, and both differ from “What may the grid operator curtail here?”. As long as everything hung off a single metering point, a meter exchange could not be separated from a supplier switch, and a PV system behind the house meter could not be balanced cleanly.
The five objects#
| Object | Short | ID | Answers | Assigned by |
|---|---|---|---|---|
| Marktlokation (market location) | MaLo | 11 digits, numeric with check digit | Where is energy supplied or generated? Tied to contract, balancing group, billing | grid operator |
| Messlokation (metering location) | MeLo | 33 characters, starting with DE | Where is it measured? Tied to the meter panel, not the device | grid operator; managed by the metering point operator |
| Netzlokation (grid location) | NeLo | 11 characters, alphanumeric | Where is the energy physically handed over to the grid – the point where grid-fee-relevant quantities such as capacity arise | grid operator |
| Technische Ressource (technical resource) | TR | 11 characters, alphanumeric | Which physical device sits behind it – PV system, battery, heat pump, charging point | grid operator |
| Steuerbare Ressource (controllable resource) | SR | 11 characters, alphanumeric | What may the grid operator control under § 14a EnWG – and via which channel | grid operator |
How the objects relate#
- MaLo ↔ MeLo: n:m
- One Marktlokation can be measured by several Messlokationen (cascade, summation meter), and one Messlokation can serve several Marktlokationen (bidirectional meter with a consumption MaLo and a feed-in MaLo). The relationship is described by calculation rules: which meters are added, which subtracted.
- MaLo ↔ TR: 1:n
- A generating Marktlokation can have several Technische Ressourcen attached – say PV modules and a battery that share the same feed-in point.
- TR ↔ SR: 1:n
- A device may or may not be controllable. If it is, the Steuerbare Ressource describes the how: control channel, control mode, § 14a agreement.
- NeLo ↔ MaLo: 1:n
- Several Marktlokationen can sit behind one grid connection point – the heat pump with reduced grid fee and the household on the same house connection.
All objects that belong together at one grid connection form a Lokationsbündel (location bundle). The bundle has no ID of its own; it is the grouping the grid operator holds together in the master data – and in which it describes the calculation steps between metering and market locations.
One house, many objects#
Detached house with PV, battery and heat pump (cascade metering)
- Netzlokation
- 1 NeLo – the house connection
- Marktlokationen
- 3 MaLo – household consumption, heat pump consumption, PV feed-in
- Messlokationen
- 2 MeLo – bidirectional meter at the house connection, sub-meter for the heat pump
- Technische Ressourcen
- 3 TR – PV system, battery storage, heat pump
- Steuerbare Ressourcen
- 1 SR – the heat pump under § 14a EnWG (the battery, if grid-friendly controlled, would be a second)
Heat pump consumption is measured as a difference: main meter minus sub-meter gives household consumption, the sub-meter alone gives the heat pump. Exactly this calculation rule is part of the master data – without it no supplier can attribute the bidirectional meter's values to its Marktlokation.
Why the model exists#
- Meter exchange without contract change: a new meter changes the meter number, not the MeLo – and certainly not the MaLo. Contract and balancing group are untouched.
- Cascades and sub-meters: without separate metering and market locations, a heat pump behind the house meter cannot be billed with its own grid fee.
- Control: § 14a EnWG requires the grid operator to know what it may control without dimming the whole connection – that is what TR and SR provide.
- Feed-in and consumption on one device: two Marktlokationen on one bidirectional meter can have different suppliers and balancing groups.
Where it shows up in MaKo#
The objects are exchanged as master data via UTILMD. The grid operator is responsible for MaLo, NeLo, TR and SR, the metering point operator for the data of the Messlokation. In the registration confirmation a supplier sees the Marktlokation with its assigned Messlokationen and calculation rule; meter values arrive via MSCONS per Messlokation and only then become quantities per Marktlokation. Master data changes – new meter, new calculation rule, new Steuerbare Ressource – run as separate UTILMD processes, triggered by whoever is responsible.