Smart metering system

A digital meter plus a smart meter gateway: measures every quarter hour, transmits encrypted, and is the precondition for dynamic tariffs and § 14a EnWG.

Updated: August 2026

The intelligent metering system is the component the digitalisation of the energy transition hangs on. Without remotely readable quarter-hourly values there are no dynamic tariffs, no grid-friendly control and no reliable consumption feedback.

How an intelligent metering system is put together

modern metering equipment + smart meter gateway

LMN

Modern metering equipment

A digital meter; measures and stores 24 months of history.

SMGW

Smart meter gateway

The communication unit certified against the BSI protection profile. It implements tariff application cases and logs every access.

WAN

External market participants

Metering point operator, grid operator, supplier – each receives only their slice.

HAN

Home network

The customer themselves, the heat pump, the wallbox, energy management.

Only the combination of modern metering equipment and a smart meter gateway makes an intelligent metering system (iMSys). The gateway is the security-certified heart of it: it collects readings, encrypts them, and gives each market participant only the data they are entitled to.

Who gets one#

CaseRule
Consumption above 6,000 kWh a yearmandatory installation
Generating installation above 7 kW of installed capacitymandatory installation
Controllable device under § 14a EnWGmandatory installation
At the customer's requestentitlement to installation within four months
All other casesmodern metering equipment, rollout until 2032

What it costs the customer#

The MsbG caps the annual charges. For modern metering equipment the cap is €25 a year. For intelligent metering systems a scale applies, based on annual consumption or installed capacity – for mandatory installation cases with high consumption it reaches €140 a year, with at most €50 on top for a control unit under § 14a. Customers who request installation themselves typically pay €40 to €50 a year.

The gateway as the security anchor#

  • Certified against the BSI protection profile and technical guideline
  • Encrypted communication outwards (WAN) and into the home network (HAN)
  • Star-shaped data distribution: each market participant receives only what they are entitled to
  • Logs every access traceably
  • Implements tariff application cases (TAF) – TAF 1 for annual consumption, TAF 7 for the register-reading series (Zählerstandsgang)

Gateway administrator and star-shaped communication#

The gateway talks to nobody directly. It is operated by the Gateway-Administrator (GWA) – normally the metering point operator or a service provider acting for it. The GWA commissions the device, manages certificates and keys, installs updates and configures which data go to whom, and how often. Star-shaped means: the gateway sends each entitled market participant – grid operator, supplier, direct marketer – exactly its own slice, encrypted and separated from the others. No recipient sees another's data, and no recipient can address the gateway itself.

CLS channel
The Controllable Local Systems channel is a transparent, encrypted tunnel through the gateway to devices in the building. Control under § 14a EnWG runs through it – the gateway itself only measures, it does not control.
Steuerbox (control box)
The device at the far end of the CLS channel: it receives the grid operator's control command and switches or dims the heat pump, wallbox or battery. It replaces the classic ripple control receiver.

Register-reading series or load curve#

Two terms that are often used interchangeably in daily work but mean different data:

Zählerstandsgang (TAF 7)Quarter-hour load curve (RLM)
What is transmitteda meter reading every 15 minutes, i.e. the cumulative register valuean energy quantity (kWh) or power (kW) per quarter hour
SourceiMSys via the GWARLM meter, see load profile
Consumption per quarter hourcalculated as the difference between two readingsmetered directly
Gapsvisible in the reading; the next reading closes themhave to be filled with substitute values
A load curve can be derived from a register-reading series, but not the other way round.