Heat pump
Turns one kilowatt-hour of electricity into three or four of heat by lifting ambient warmth to a usable temperature.
A heat pump does not create heat, it moves it – from outside to inside, against the natural temperature gradient. The drive energy for that is electricity, and the ratio of heat gained to electricity spent is the number that decides everything.
JAZ and COP#
- COP (coefficient of performance)
- The instantaneous value on the test bench, at defined temperatures. Marketing-friendly, but says little about everyday operation.
- JAZ (Jahresarbeitszahl, seasonal performance factor)
- The real ratio across a whole year, including cold days, defrost cycles and the immersion heater. This is the number that counts.
JAZ = Heat delivered [kWh] ÷ Electricity consumed [kWh]
- JAZ 3.5
- 1 kWh of electricity becomes 3.5 kWh of heat – 71 % comes free from the environment
- Typical
- 3.2–3.8 for air-to-water, 4.0–4.5 for brine-to-water
Heat pump or gas boiler?
Running costs per year
interactive4,167 kWh of electricity at an SPF of 3.6
16,304 kWh of gas at 92 % efficiency
At these prices the tipping point sits at an SPF of 2.01. Above that the heat pump wins, below it the boiler.
Energy costs only, excluding purchase, maintenance and subsidies. The seasonal performance factor is the decisive figure: it says how many kilowatt-hours of heat come out of one kilowatt-hour of electricity. Typical values are 3.2 to 3.8 for air-to-water and 4.0 to 4.5 for brine-to-water heat pumps.
What efficiency depends on#
- Flow temperature – the biggest lever. Underfloor heating at 35 °C instead of radiators at 55 °C lifts the JAZ by roughly 1.0
- Heat source – see the types: ground beats outside air, especially in winter
- Hydraulic balancing and correct sizing – an oversized unit cycles and loses efficiency
- The immersion heater – every kilowatt-hour from the electric backup pushes the JAZ straight down
Tariff and grid fee#
Heat pumps above 4.2 kW fall under § 14a EnWG: the grid operator may curtail them to 4.2 kW in an emergency, and in exchange the grid fees are reduced – either as Modul 1 (a flat reduction), Modul 2 (a percentage reduction of the Arbeitspreis, the unit rate, which requires a separate metering point) or, since 1 April 2025, additionally Modul 3 (a time-variable grid fee, only in combination with Modul 1). With a separate meter, heat pump tariffs in 2026 run at roughly 21 to 26 ct/kWh instead of the 33 to 40 ct/kWh of a household tariff.